The equivalent in iMRS Prime are as follows: In both configuration, SET bundle added HRV finger sensor (iMORE or Sense) and Brainwave Entrainment System (iSLRS or Brain) respective. In iMRS Prime, there are 2 additional model not available in iMRS No. You cannot use the old iMRS applicators or iSLRS with the new iMRS Prime system for two reasons: (1) the interface connector is different and (2) the chip board and communicating protocol is entirely different. The iMORE finger sensor, however share the same connector interface, and it may still be used, though not officially supported by Swiss Bionic Solutions. Both iMRS Prime and Omnium1 are built on the same technology and application principle. Meaning the frequency range, intensity of both the full-body mattress and pad/pillow are essentially the same. The key unique features available in iMRS PRIME are Check out this article: iMRS Prime vs Omnium1 for in-depth analysis of the differences No. Prime and Omnium1 uses different operating platform, despite they share similar technical foundation and similarities in design. The physical connector design is different is both series too. Therefore you cannot use any of the components, including power supply between the systems. iMRS PRIME contol panel, connector box, Exagon Mat/FIR, Pad, and Spot all comes with three years warranty, usually on a 1-to-1 replacement if not there are no replaceable components to swap/repair. Customers will have to send the item to the nearest service center at their own cost, with free 1-way return shipping from the service center, for warranty parts. Accessories and other components warranty are as follow: Swiss Bionic Solutions also offers extended 1 and 2 years warranty for main components only as Carefree 48 (1 year) and Carefree 60 (2 years). Before sending back the item, always log an official support case at https://support.swissbionic.com/support Starting 2.08 and above, the firmware packaging has changed and is in .ppkg single file format instead. The upgrade package size is much smaller at around 100MB + and takes less than 5 minutes to upgrade, instead of 10-20 minutes. The upgrade process remains the same. This is the general procedure for iMRS Prime upgrade for version 2.00 and before. You need to have a PC/Mac and a USB storage to complete the procedure. In essence, the process is: 3. Insert the USB to the iMRS Prime Control Unit (see figure below) Under Settings (wheel symbol in the main menu), select -> System information and then select System update. Click the Start update button. The update may takes 15-30 minutes, depending on the firmware version. The screen might be upside down after the update. To correct the rotation, follow the following procedure: The general information of this guide is also applicable to both Exagon Sense and iMORE 2.0 Finger sensor as the hardware technology essentially is the same. To properly troubleshoot the Finger sensor, you need to first understand the working of the technology. iMORE is using photoplethysmogram (PPG) technology, that uses optically obtained plethysmogram to detect blood volume changes in the microvascular bed of tissue. It illuminates the skin and measures changes in light absorption. PPG reading used for Heart Rate Variability (HRV) runs at a much higher sampling rate as it needs to pick up every heartbeat and the differences in the millisecond range, as compared to general heartbeat monitoring sensor which they usually just take beats average or using extrapolation technique. The iMRS HRV assessment is based on per-minute interval. The system will evaluate the heartbeat variability within each minute window, and report a value between 1-7 as an indicative range of your HRV, so the iMRS system will use this value to adjust the session intensity accordingly. In general, people with higher HRV (higher value) means he/she has higher recovery potential, and hence is able to subject to higher exposure of external stimulation. If there are too many missing beats during the reading interval, the system may refuse to report a value for that specific interval, hence you will not see any value in the HRV chart for that interval. This section is applicable to iMRS system only Of course, there is a possibility of hardware sensor failure. Contact the nearest Swiss Bionic Solutions office for further support.Features
General
Main Components Warranty
Extended Warranty
Support
Detailed Procedure
Completing the Update
HRV Finger Sensor Troubleshooting Guide
Key reasons for intermittent and inaccurate reading are:
How to check your iMRS controller is configured correctly (applicable to iMRS system)
nc – when the iMORE is not physically plugged in
sc – when the iMORE is physically plugged in but not clipped on to a finger
heartbeat sign & rate – when the iMORE is clipped on to a fingerLoad More
FAQ
Category: Features
Category: Features
Category: Features
Category: General
Category: General
Category: Support
Category: Support